1 36000115752 2018-08-13T10:55:12-04:00 Learn how to connect ThinkRF R5500 to Keysight VSA software 36000180928 false Getting Started 2 2018-08-13T10:55:12-04:00 1 1 2018-08-13T11:44:11-04:00 1 0 You must install the following Keysight software on your PC before installing the ThinkRF E300 Enabler: Keysight 89600 VSA software, Version 22.21 or later Keysight Connection Expert (part of the IO Libraries suite), Version 2018 Update 1 or later Keysight Multi-vendor Hardware Connectivity (Option 301) Installing the Keysight VSA 89600 Software You can download and install the Keysight 89600 VSA software and the Multi-vendor Hardware Connectivity (Option 301) from the Keysight Technologies website. For detailed instructions, including licensing requirements, visit the Keysight VSA 89600 software page. Make sure your local PC account has administrative privileges before installing the software. Installing the Keysight Connection Expert The Keysight Connection Expert is one of the utilities included in the Keysight IO Libraries suite, and is used to discover devices on the local network. You can download and install the IO Libraries suite from the Keysight IO Libraries page. <p><span style="font-size: 16px;">You must install the following Keysight software on your PC before installing the ThinkRF E300 Enabler:</span></p><ul><li><span style="font-size: 16px;">Keysight 89600 VSA software, <strong>Version 22.21</strong> or later</span></li><li><span style="font-size: 16px;">Keysight Connection Expert (part of the IO Libraries suite), <strong>Version 2018 Update 1 </strong>or later</span></li><li><span style="font-size: 16px;">Keysight Multi-vendor Hardware Connectivity (<strong>Option 301</strong>)</span></li></ul><hr><p><span style="font-size: 16px;"><span style="font-size: 16px;"></span></span></p><p><span style="font-size: 16px;"><strong>Installing the Keysight VSA 89600 Software</strong></span></p><p><span style="font-size: 16px;">You can download and install the Keysight 89600 VSA software and the Multi-vendor Hardware Connectivity (Option 301) from the Keysight Technologies website.</span></p><p><br></p><p><span style="font-size: 16px;">For detailed instructions, including licensing requirements, visit </span><a href="https://www.keysight.com/ca/en/software/application-sw/89600-vsa-software.html" rel="noreferrer noopener" target="_blank"><span style="font-size: 16px;">the Keysight VSA 89600 software</span></a><span style="font-size: 16px;"> page.</span></p><p><br></p><p><span style="font-size: 16px;">Make sure your local PC account has administrative privileges before installing the software.</span></p><hr><p><span style="font-size: 16px;"><strong>Installing the Keysight Connection Expert</strong></span></p><p><span style="font-size: 16px;">The Keysight Connection Expert is one of the utilities included in the Keysight IO Libraries suite, and is used to discover devices on the local network.</span></p><p><br></p><p><span style="font-size: 16px;">You can download and install the IO Libraries suite from the </span><a href="https://www.keysight.com/en/pd-1985909/io-libraries-suite?nid=-33330.977662&amp;cc=CA&amp;lc=eng" rel="noreferrer noopener" target="_blank"><span style="font-size: 16px;">Keysight IO Libraries</span></a><span style="font-size: 16px;"> page.</span></p> 36000180928 386 36000077363 2019-01-16T15:43:32-05:00 36001028276 1 Install Keysight VSA 89600 and Keysight Connection Expert Learn how to install Keysight VSA and coneection expert on your PC VSA,Keysight,89600,R5500,ThinkRF 2 1 0 1. Installing the Keysight VSA 89600 and Keysight Connection Expert Software 2018-08-13T11:44:11-04:00 36001028276 1 2018-08-13T14:36:53-04:00 0 0 If you do not already have a copy of the ThinkRF E300 Enabler, you can obtain the software from ThinkRF, by sending an email to support@thinkrf.com or by downloading the software from the ThinkRF website. The Setup wizard installs the ThinkRF E300 Enabler on your PC. Double-click on the thinkRF thinkRF E300 -2.0.exe file to launch the Setup Wizard. Review the End User License Agreement (EULA) and click Next. In the Ready to Install window, click Install. When installation is complete, click Finish. Note:  If the Setup Wizard detects that you do not have the .NET Framework installed, you are prompted to install it. Follow the instructions in the Wizard. If the Setup Wizard detects that you do not have the Keysight 89600 VSA software installed, the Wizard displays an error message and aborts the installation. <p><span style="font-size: 16px;">If you do not already have a copy of the ThinkRF E300 Enabler, you can obtain the software from ThinkRF, by sending an email to support@thinkrf.com or by downloading the software from the ThinkRF website.</span></p><p><span style="font-size: 16px;">The Setup wizard installs the ThinkRF E300 Enabler on your PC.</span></p><ol><li><span style="font-size: 16px;">Double-click on the thinkRF thinkRF E300 -2.0.exe file to launch the Setup Wizard.</span><br><span style="font-size: 16px;"><img src="https://i.snag.gy/Zi72Vm.jpg" class="fr-dii fr-draggable"></span><br><br></li><li><span style="font-size: 16px;">Review the End User License Agreement (EULA) and click Next.</span><br><span style="font-size: 16px;"><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013516991/original/3ktMS0iksVsWbPubuOCzX8iB6fmZ-aFUDg?1534185872" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013516991/original/3ktMS0iksVsWbPubuOCzX8iB6fmZ-aFUDg?1534185872" data-fileid="36013516991" data-uniquekey="1534185795125" style="width: 424px; height: 319.487px;"></span><br></li><li><span style="font-size: 16px;">In the Ready to Install window, click Install.</span><br><span style="font-size: 16px;"><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013517006/original/uq00-edfiHopxoOO9sV2jbVoFXTiQ5ttWQ?1534185896" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013517006/original/uq00-edfiHopxoOO9sV2jbVoFXTiQ5ttWQ?1534185896" data-fileid="36013517006" data-uniquekey="1534185795125" style="width: 426px; height: 320.994px;"></span><br></li><li><span style="font-size: 16px;">When installation is complete, click Finish.</span><br><span style="font-size: 16px;"><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013517024/original/ZsSiFA06IzSfcUsqNKXUnllhfySYmVpCdQ?1534185922" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013517024/original/ZsSiFA06IzSfcUsqNKXUnllhfySYmVpCdQ?1534185922" data-fileid="36013517024" data-uniquekey="1534185795125" style="width: 425px; height: 320.24px;"></span></li><p><br></p></ol><p><span style="font-size: 16px;"></span></p><hr><p><span style="font-size: 16px;"></span><span style="font-size: 16px;">Note: </span></p><ul><li><span style="font-size: 16px;">If the Setup Wizard detects that you do not have the .NET Framework installed, you are prompted to install it. Follow the instructions in the Wizard.</span></li><li><span style="font-size: 16px;">If the Setup Wizard detects that you do not have the Keysight 89600 VSA software installed, the Wizard displays an error message and aborts the installation.</span></li></ul> 36000180928 107 36000077376 2019-01-16T15:43:46-05:00 36001028276 2 Install ThinkRF E300 Enabler Learn how to install ThinkRF E300 enabler on your PC VSA,Keysight,89600,R5500,ThinkRF 2 0 0 2. Installing the ThinkRF E300 Enabler 2018-08-13T14:36:53-04:00 36001028276 1 2018-08-13T15:31:50-04:00 0 0 When you have installed the Keysight software and the ThinkRF E300 Enabler, you must use the Keysight Connection Expert to discover the ThinkRF R5xx0 device(s) on the local subnet. Note: ThinkRF devices use High-Speed LAN Instrument Protocol (HiSLIP), a TCP/IP-based protocol for remote control of LAN-based test and measurement instruments. Launch the Keysight Connection Expert application. In the Keysight Connection Expert dashboard, click on the Add button, then select LAN instrument from the drop-down menu. The system opens the Add a LAN device window that displays all discovered devices on the local subnet. In the Add a LAN device window, select an Rxx00 device from the list of detected devices and click OK. If your device is not listed, is connected wirelessly to the subnet, or has a public IP address, click on the Enter Address tab. On the Enter Address tab, enter the device IP address and select the HiSlip protocol, then click OK. The application displays the connected devices in the Instruments tab (under “My Instruments). When you click on a device in the list, the device details appear in the right-side pane. <p><span style="font-size: 16px;">When you have installed the Keysight software and the ThinkRF E300 Enabler, you must use the Keysight Connection Expert to discover the ThinkRF R5xx0 device(s) on the local subnet.</span></p><p><br></p><p><span style="font-size: 16px;"><strong>Note</strong>: ThinkRF devices use High-Speed LAN Instrument Protocol (HiSLIP), a TCP/IP-based protocol for remote control of LAN-based test and measurement instruments.</span></p><p><br></p><ol><li><span style="font-size: 16px;">Launch the Keysight Connection Expert application.<br><img src="https://i.snag.gy/HkgLS5.jpg" class="fr-dii"><br><br></span></li><li><span style="font-size: 16px;">In the Keysight Connection Expert dashboard, click on the Add button, then select LAN instrument from the drop-down menu.</span><br><span style="font-size: 16px;"><img class="fr-dib fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013519213/original/4m6wfn9RClnyfGOBA7lz3AjUA8ZNVDaIYQ?1534187981" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013519213/original/4m6wfn9RClnyfGOBA7lz3AjUA8ZNVDaIYQ?1534187981" data-fileid="36013519213" data-uniquekey="1534186054941" style="width: 607px; height: 323.619px;"></span><br><span style="font-size: 16px;">The system opens the <strong>Add</strong><strong> a LAN device</strong> window that displays all discovered devices on the local subnet.<br></span><img class="fr-dib fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013519269/original/sreDA5tTjEH1oVign5_HpGjOlRFI4PPkEA?1534188022" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013519269/original/sreDA5tTjEH1oVign5_HpGjOlRFI4PPkEA?1534188022" data-fileid="36013519269" data-uniquekey="1534186054941"><br></li><li><span style="font-size: 16px;">In the <strong>Add a LAN device</strong> window, select an Rxx00 device from the list of detected devices and click <strong>OK</strong>.<br><br></span></li><li><span style="font-size: 16px;">If your device is not listed, is connected wirelessly to the subnet, or has a public IP address, click on the <strong>Enter Address</strong> tab.<br><br></span></li><li><span style="font-size: 16px;">On the <strong>Enter Address</strong> tab, enter the device IP address and select the <strong>HiSlip </strong>protocol, then click <strong>OK</strong>.</span><br><img class="fr-dib fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013519852/original/qkXStm9EJColHuAIqxOYrYskNpWgw7cd4A?1534188514" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013519852/original/qkXStm9EJColHuAIqxOYrYskNpWgw7cd4A?1534188514" data-fileid="36013519852" data-uniquekey="1534186054941" style="width: 476px; height: 497.783px;"><br><span style="font-size: 16px;">The application displays the connected devices in the Instruments tab (under “My Instruments). When you click on a device in the list, the device details appear in the right-side pane.<br></span><img class="fr-dib fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013519921/original/7q6Wr17e50eiqJR8_G-Mw91F9suV2IFWRQ?1534188559" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013519921/original/7q6Wr17e50eiqJR8_G-Mw91F9suV2IFWRQ?1534188559" data-fileid="36013519921" data-uniquekey="1534186054941"></li></ol> 36000180928 72 36000077383 2020-04-17T16:43:30-04:00 36001028276 3 Discovery ThinkRF devices on VSA Learn how to add ThinkRF devices to Keysight VSA software. Vsa 2 0 0 3. Discovering ThinkRF R5xx0 Devices 2018-08-13T15:31:50-04:00 36001028276 1 2018-08-13T15:39:02-04:00 0 0 The Keysight VSA has a default Analyzer configuration profile that is enabled when you launch the application. The first time you use the Keysight VSA application with a R5500 device, you must create a configuration profile for the R5500 device you are using, as described in the following section. Creating the ThinkRF Analyzer Configuration Before you can monitor signal data from the R5500 device, you must add a hardware configuration profile for this device. In the VSA application menu bar, open the Utilities menu, and select the Hardware > Configurations … option from the drop-down menu. In the Hardware window, click on the Add button to add a new hardware configuration. In the New Hardware Configuration window: Select the ThinkRF R5500 entry in the Possible Logical Instruments pane, and click the “>” arrow to add it to the Configuration pane. Leave the default values in the Select the instrument(s) to use field. Specify a name for your analyzer in the Name the configuration field. Click OK to create the hardware configuration. The ThinkRF Analyzer configuration appears in the Configurations tab. In the Current Analyzer Configuration field, select the new ThinkRF R5500 device from the drop-down menu. Close the Hardware window. The VSA spectrum display shows signal data from the R5500 device. <p><span style="font-size: 16px;">The Keysight VSA has a default Analyzer configuration profile that is enabled when you launch the application.</span></p><p><span style="font-size: 16px;">The first time you use the Keysight VSA application with a R5500 device, you must create a configuration profile for the R5500 device you are using, as described in the following section.</span></p><p><br></p><p><br></p><p><span style="font-size: 16px;"><strong>Creating the ThinkRF Analyzer Configuration</strong></span></p><p><span style="font-size: 16px;">Before you can monitor signal data from the R5500 device, you must add a hardware configuration profile for this device.</span></p><ol><li><span style="font-size: 16px;">In the VSA application menu bar, open the <strong>Utilities </strong>menu, and select the <strong>Hardware &gt; Configurations</strong> … option from the drop-down menu.<br><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013520526/original/MgKfU-VukJGiDdnRWNK3R-FCwnN5bKiSTg?1534189131" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013520526/original/MgKfU-VukJGiDdnRWNK3R-FCwnN5bKiSTg?1534189131" data-fileid="36013520526" data-uniquekey="1534188974143"></span><br></li><li><span style="font-size: 16px;">In the <strong>Hardware</strong> window, click on the <strong>Add </strong>button to add a new hardware configuration.<br><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013520672/original/iF3WcC7qGHcm-kZBHpJqrjZ0xx03FfeDmg?1534189269" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013520672/original/iF3WcC7qGHcm-kZBHpJqrjZ0xx03FfeDmg?1534189269" data-fileid="36013520672" data-uniquekey="1534189197753"><br></span></li><li><p><span style="font-size: 16px;">In the <strong>New Hardware Configuration</strong> window:</span></p><ol><li><p><span style="font-size: 16px;">Select the ThinkRF R5500 entry in the <strong>Possible Logical Instruments</strong> pane, and click the “&gt;” arrow to add it to the <strong>Configuration </strong>pane.</span></p></li><li><p><span style="font-size: 16px;">Leave the default values in the <strong>Select the instrument(s) to use</strong> field.</span></p></li><li><p><span style="font-size: 16px;">Specify a name for your analyzer in the <strong>Name the configuration</strong> field.</span><br><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013520854/original/IrQO1U5rHEg_5RE9FeWdS3zmNY7QurosBg?1534189455" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013520854/original/IrQO1U5rHEg_5RE9FeWdS3zmNY7QurosBg?1534189455" data-fileid="36013520854" data-uniquekey="1534189197753"><span style="font-size: 16px;"><br></span></p></li><li><p><span style="font-size: 16px;">Click <strong>OK </strong>to create the hardware configuration.<br>The ThinkRF Analyzer configuration appears in the <strong>Configurations</strong> tab.<br><br></span></p></li><li><p><span style="font-size: 16px;">In the <strong>Current Analyzer Configuration</strong> field, select the new ThinkRF R5500 device from the drop-down menu.<br><br></span></p></li><li><p><span style="font-size: 16px;">Close the <strong>Hardware </strong>window.<br>The VSA spectrum display shows signal data from the R5500 device.</span></p></li></ol></li></ol> 36000180928 76 36000077385 2019-01-16T15:44:03-05:00 36001028276 4 Configure ThinkRF E300 Enabler Learn how to configure ThinkRF E300 enabler within Keysight VSA software VSA,Keysight,89600,R5500,ThinkRF,E300 2 0 0 4. Configuring the ThinkRF E300 Enabler 2018-08-13T15:39:02-04:00 36001028276 1 2018-08-13T15:59:04-04:00 0 0 You can obtain device-specific information for your ThinkRF R5500 device from the VSA application. In the VSA application menu bar, open the Utilities menu, and select the Hardware > Configurations … option from the drop-down menu. In the Hardware window, click on the ThinkRF analyzer configuration profile for your R5500 device. Click the arrow (>) above the Properties label to expand the window and display the Properties pane. Device information (including model, serial number and firmware revision) appears in the Properties pane on the right. <p><span style="font-size: 16px;">You can obtain device-specific information for your ThinkRF R5500 device from the VSA application.</span></p><ol><li><span style="font-size: 16px;">In the VSA application menu bar, open the <strong>Utilities </strong>menu, and select the <strong>Hardware </strong>&gt; <strong>Configurations </strong>… option from the drop-down menu.</span><br><br></li><li><span style="font-size: 16px;">In the <strong>Hardware </strong>window, click on the ThinkRF analyzer configuration profile for your R5500 device.</span><br><br></li><li><span style="font-size: 16px;">Click the arrow (&gt;) above the <strong>Properties </strong>label to expand the window and display the <strong>Properties </strong>pane.</span><br><span style="font-size: 16px;"><br>Device information (including model, serial number and firmware revision) appears in the <strong>Properties </strong>pane on the right.<br><br><img class="fr-dib fr-draggable" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013521835/original/TM-o-SW9N73K5lhhujoB6aQcBYce2hhqbQ?1534190280" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013521835/original/TM-o-SW9N73K5lhhujoB6aQcBYce2hhqbQ?1534190280" data-fileid="36013521835" data-uniquekey="1534190143077" style="width: 667px; height: 364.203px;"></span></li></ol> 36000180928 63 36000077387 2019-01-16T15:44:08-05:00 36001028276 5 View Thinkrf device information in Keysight VSA software Learn how to view the ThinkRF device detail information in Keysight VSA software VSA,Keysight,89600,R5500,ThinkRF,E300 2 0 0 5. Viewing Device Information in Keysight VSA 2018-08-13T15:59:04-04:00 36001028276 1 2018-08-13T16:00:35-04:00 0 0 You can configure device-specific settings for the R5500, including signal attenuation, gain, and reference clock, from the VSA application, as described below. Note: Gain and attenuation settings allow the R5500-VSA application to accommodate very weak signals as well as strong signals. You must remain within the signal strength levels specified in the R5500 data sheet to avoid saturating or damaging the device. In the VSA application menu bar, open the Input menu, and select the Extensions … option from the drop-down menu. The Input dialog window opens and displays the Extensions tab. On the Extensions tab, set values for the following parameters: • Attenuation (db): sets the attenuation of the input signal to one of four attenuation levels (0, 10, 20, or 30 dB). • Gain: controls the gain blocks inside the Front-End of the R5500 device, where three gain levels are available (low, medium, or high). Note: The ThinkRF R5500-408 device and its variants have no controllable gain stage. Therefore, gain setting is set to “NotApplicable”     • Level Trigger: specifies the trigger configuration, where four parameters are available: ▪ Lev. Trig. Start Frequency (Hz): specifies start frequency for the triggering window in Hz. ▪ Lev. Trig. Stop Frequency (Hz): specifies stop frequency for the triggering window in Hz. ▪ Level Trigger Enabled: enables/disables level triggering. ▪ Level Trigger Level (dBm): specifies the triggering threshold value in dBm. • Reference Clock (10 MHz): specifies the source of the 10 MHz reference clock. You can select the internal (built-in) 10 MHz source, or an external source.     If you are using an external source for the reference clock, you must connect it via the associated port on the rear panel of the R5500 device (10 Mhz/IN), and carefully consider input damage     levels.     The LED associated with the external reference source has the following states:     ▪ Solid green: Internal reference frequency is selected.     ▪ Blinking green: External reference frequency is selected, and an input source is connected.     ▪ Blinking red: External Note: When you add a new measurement to a R5500 device in the VSA application (MeasSetup > New Measurement), you must close the Input dialog window first. <p><span style="font-size: 16px;">You can configure device-specific settings for the R5500, including signal attenuation, gain, and reference clock, from the VSA application, as described below.<br><br><strong>Note</strong>: Gain and attenuation settings allow the R5500-VSA application to accommodate very weak signals as well as strong signals. You must remain within the signal strength levels specified in the R5500 data sheet to avoid saturating or damaging the device.</span></p><ol><li><span style="font-size: 16px;">In the VSA application menu bar, open the <strong>Input </strong>menu, and select the <strong>Extensions </strong>… option from the drop-down menu.<br><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013522215/original/QIIRXhACJ_G3LxuZ4KqiA1oZAzttOp1gTw?1534190637" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013522215/original/QIIRXhACJ_G3LxuZ4KqiA1oZAzttOp1gTw?1534190637" data-fileid="36013522215" data-uniquekey="1534190589404"><br>The <strong>Input </strong>dialog window opens and displays the <strong>Extensions </strong>tab.<br><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013522259/original/-47ajrBrl_lKfLjXpKP65eO35Wn3KRiy-g?1534190684" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013522259/original/-47ajrBrl_lKfLjXpKP65eO35Wn3KRiy-g?1534190684" data-fileid="36013522259" data-uniquekey="1534190589404" style="width: 369px; height: 464.495px;"><br><br></span></li><li><p><span style="font-size: 16px;">On the <strong>Extensions </strong>tab, set values for the following parameters:<br>• <strong>Attenuation (db)</strong>: sets the attenuation of the input signal to one of four attenuation levels (0, 10, 20, or 30 dB).<br>• <strong>Gain</strong>: controls the gain blocks inside the Front-End of the R5500 device, where three gain levels are available (low, medium, or high).<br><br><strong>Note</strong>: The ThinkRF R5500-408 device and its variants have no controllable gain stage. Therefore, gain setting is set to “NotApplicable”<br>   <br>• <strong>Level Trigger</strong>: specifies the trigger configuration, where four parameters are available:<br>▪ <strong>Lev. Trig. Start Frequency (Hz)</strong>: specifies start frequency for the triggering window in Hz.<br>▪ <strong>Lev. Trig. Stop Frequency (Hz)</strong>: specifies stop frequency for the triggering window in Hz.<br>▪ <strong>Level Trigger Enabled</strong>: enables/disables level triggering.<br>▪ <strong>Level Trigger Level (dBm)</strong>: specifies the triggering threshold value in dBm.<br>• <strong>Reference Clock (10 MHz)</strong>: specifies the source of the 10 MHz reference clock. You can select the internal (built-in) 10 MHz source, or an external source.<br>    If you are using an external source for the reference clock, you must connect it via the associated port on the rear panel of the R5500 device (10 Mhz/IN), and carefully consider input damage     levels.<br>    The LED associated with the external reference source has the following states:<br>    ▪ Solid green: Internal reference frequency is selected.<br>    ▪ Blinking green: External reference frequency is selected, and an input source is connected.<br>    ▪ Blinking red: External<br><br><strong>Note</strong>: When you add a new measurement to a R5500 device in the VSA application (<strong>MeasSetup </strong>&gt; <strong>New Measurement</strong>), you must close the <strong>Input </strong>dialog window first.<br><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013522443/original/jT8flhrUGwMPz0emm_ZsH1yBDwlpznrSpw?1534190885" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013522443/original/jT8flhrUGwMPz0emm_ZsH1yBDwlpznrSpw?1534190885" data-fileid="36013522443" data-uniquekey="1534190589404"><img class="fr-dib fr-draggable fr-fil" src="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013522451/original/p6V0yv7gcfSr9w55D6BAEDefsGyHBWIR0g?1534190893" data-filelink="https://s3.amazonaws.com/cdn.freshdesk.com/data/helpdesk/attachments/production/36013522451/original/p6V0yv7gcfSr9w55D6BAEDefsGyHBWIR0g?1534190893" data-fileid="36013522451" data-uniquekey="1534190589404" style="width: 687px; height: 351.825px;"></span></p></li></ol> 36000180928 50 36000077388 2019-01-16T15:44:13-05:00 36001028276 6 configure R5500 in Keysight VSA Learn how to configure ThinkRF R5500 in Keysight VSA VSA,Keysight,89600,R5500,ThinkRF,E300 2 0 0 6. Configuring R5500 Device Settings in Keysight VSA 2018-08-13T16:00:35-04:00 36001028276